Electrical Rooms

Intercell in Electrical Rooms

In electrical rooms for low voltage, medium voltage, high voltage and Motor Control Centers, safety, clarity and accessibility are not secondary concerns. Intercell provides the infrastructure you need to achieve this.

LS/MS/HS & MCC

Safe and structured cable management in electrical rooms

Electrical rooms for low voltage (LV), medium voltage (MV), high voltage (HV) and Motor Control Centers (MCC) place the highest demands on safety, clarity and accessibility. Cables and conduits must be neatly organised, always accessible for maintenance and inspection, and fully compliant with applicable safety standards. A cluttered or inaccessible floor is not an option here — not only due to the safety of the personnel who work there daily, but also because of the statutory requirements imposed on these types of facilities.
Intercell offers the ideal solution for this. The modular floor system routes all cables and conduits neatly beneath the floor, creates a clear and safe working environment, and always provides rapid access for maintenance and inspection — without demolition work and without disruption. This allows you to focus on what truly matters: a safe and reliable electrical installation.

Why Intercell in electrical rooms?

In electrical rooms, safety and clarity are not a luxury but an absolute requirement. The consequences of a poorly organised or inaccessible electrical room can be significant — from hazardous situations for staff to costly failures in the electrical installation. Intercell is designed to minimise those risks. The system neatly conceals all cables and conduits beneath the floor, provides quick access at all times for maintenance and inspection, and meets the most stringent fire and safety standards. Below are the six key benefits for your electrical room.

01

Safe cable management

All cables and conduits are neatly concealed beneath the floor. No loose cables, no trip hazards, and a well-organised space that meets safety standards.

02

Instant access at all times

The floor panels can be removed in no time for inspection, maintenance, or repair. No demolition work, no disruption, and minimal interference with ongoing operations.

03

Fire safe

Intercell has been fire-resistance tested in accordance with EN13501-1 and EN13501-2, class Afl-s1. In electrical rooms where fire safety is critical, Intercell provides the required assurance.

04

Electromagnetic compatibility

Intercell has been EMC tested, achieving a reduction of 25 dB between 3 and 30 MHz and 20 dB between 30 and 1000 MHz. Essential in environments with high concentrations of electrical installations.

05

High load capacity

Class 4B in accordance with EN12825, with a maximum load of more than 9 kN. Suitable for heavy electrical installations and switchgear cabinets.

06

No additional cable trays

Intercell eliminates the need for separate cable trays. Everything is already integrated into the system, reducing costs and keeping the space well organised.

Designed for Critical Environments

Electrical rooms are critical environments where there is no margin for error. A cluttered or inaccessible floor can lead to hazardous situations for staff, delays in maintenance, and increased costs for the organisation. Intercell prevents this by routing all cables and conduits neatly beneath the floor while always providing rapid access for inspection and repair.
The system installs quickly on a levelled floor — no drilling, no demolition work required. The floor panels can always be removed with ease for inspection or repair, and the system meets the most stringent fire and safety standards. This allows you to focus entirely on what truly matters: a safe, reliable, and well-organised electrical installation that complies with all applicable laws and regulations.

Technical specifications

Intercell meets the most stringent standards for load capacity, fire safety, and electromagnetic compatibility. This makes the system exceptionally well-suited for use in electrical rooms where high demands are placed on the safety and reliability of the installation. Below are the key technical specifications for use in LV, MV, HV, and MCC rooms.

4B

Class EN12825

Max. load > 9 kN, deflection < 2.5mm.

25 dB

EMC attenuation

Between 3 and 30 MHz. Essential in environments with a high density of electrical installations.

Afl-s1

Fire classification

Tested in accordance with EN13501-1 and EN13501-2.

Frequently Asked Questions

Is Intercell suitable for use in an electrical room?

Yes, Intercell is ideally suited for electrical rooms for LV, MV, HV and MCC. The system neatly conceals all cables and conduits beneath the floor, provides immediate access for inspection and maintenance at all times, and complies with the most stringent fire and safety standards.

Can I access the cables and conduits for maintenance or inspection?

Yes, the floor panels can be removed easily and without tools. You always have rapid access to the cables and conduits for inspection, maintenance or repair, without any demolition work or disruption.

Is Intercell sufficiently fire-safe for use in an electrical room?

Yes, Intercell has been fire-resistance tested in accordance with EN13501-1 and EN13501-2, class Afl-s1. The system meets the most stringent fire safety standards for use in electrical rooms and other critical environments.

Does Intercell have EMC certification?

Yes, Intercell has been tested for electromagnetic compatibility (EMC), with an attenuation of 25 dB between 3 and 30 MHz and 20 dB between 30 and 1000 MHz. This is essential in electrical rooms housing extensive electrical installations and high-voltage equipment.

Is Intercell capable of supporting heavy electrical installations and switchgear cabinets?

Yes, Intercell is certified in accordance with EN12825, Class 4B, and can withstand a maximum point load of more than 9 kN. The system is designed for use in rooms containing heavy electrical installations and switchgear cabinets.

Does Intercell affect the load-bearing capacity of the building?

Intercell is a lightweight system that adds only 22 kg/m² to the structure. This makes the system suitable for both new and existing buildings, even where the load-bearing capacity of the floor is limited.

Are additional cable ducts required alongside Intercell?

No, Intercell eliminates the need for separate cable ducts.  within the system itself, which reduces costs and keeps the space more organised and accessible.