The foundation of every control room
In a control room or dispatch centre, reliability is not a luxury — it is an absolute requirement. Workstations are packed with computers, monitors, and communications equipment, all of which require a neat, organised cable infrastructure that is always accessible for modifications and expansions. A cluttered or inaccessible floor is simply not an option here, not only for reasons of clarity but also for the safety of the personnel who work there around the clock.
Intercell provides the ideal solution. The modular floor system routes all cables, power connections, and data connections cleanly beneath the floor, keeping the workspace consistently tidy and professional. And whenever adjustments are required, the floor panels can be removed in no time — without downtime, without disruption, and without interference with ongoing operations. This allows you to focus entirely on what truly matters: a reliable and well-organised control room or dispatch centre that performs optimally 24 hours a day, 7 days a week.
Why Intercell in control rooms and dispatch centres?
Control rooms and dispatch centres place unique demands on infrastructure. Everything must function correctly, at all times, as a failure or inaccessible cable infrastructure can have serious consequences for operational continuity. At the same time, control rooms and dispatch centres must scale with the organisation — new workstations are added, additional screens are installed, and technology is continuously expanded. Intercell is designed to meet all these requirements, from initial installation through to the final expansion. Below are the four key benefits for your environment.
1. Organised cable management
In a control room, dozens — sometimes hundreds — of cables run simultaneously: power, data, communications, and signal connections. All these cables must be neatly organised, permanently accessible for maintenance and expansion, and completely free of trip hazards for personnel moving through the space around the clock. Intercell routes all cables cleanly beneath the floor, with no exposed conduits or tangled wiring. The result is a well-ordered, professional workspace where everything is in its place and employee concentration is not disrupted by a cluttered environment.
2. Rapid access at all times
Does a cable need replacing, a connection adding, or a fault resolving? In a control room or dispatch centre, this must be achievable quickly, without disrupting ongoing operations. Intercell floor panels can be removed and replaced in no time — no demolition work, no inconvenience, and minimal disruption to operations. This enables you to respond swiftly to faults or expansion requirements, regardless of the time of day.
3. Flexible for expansion
Control rooms and dispatch centres grow alongside the organisation. New workstations are added, additional screens are installed, and more equipment is connected. With a traditional floor system, expansion is often a time-consuming and costly undertaking. With Intercell, it is entirely different. Cables are rerouted, new connections are added, and the floor is relaid — all without major renovation work and without extended periods of downtime.
4. Electromagnetic compatibility
In a control room or dispatch centre, numerous electronic devices operate in close proximity. This can lead to electromagnetic interference, which may compromise the reliability of communication and control systems. Intercell has been tested for electromagnetic compatibility (EMC), achieving an attenuation of 25 dB between 3 and 30 MHz and 20 dB between 30 and 1000 MHz. This makes the system particularly well suited to environments where electromagnetic interference poses a risk to installation reliability.
Designed for 24/7 use

Control rooms and dispatch centres often operate around the clock, seven days a week. This means that modifications to the infrastructure must be carried out quickly and efficiently, without disrupting ongoing operations and without extended periods of downtime. Intercell makes this possible. The floor panels are easy to remove and reposition, ensuring that adjustments can always be implemented swiftly and without inconvenience — outside office hours or in the middle of the night.
Thanks to the floor boxes for power and RJ45 connections, every workstation has exactly the connections it needs, precisely where they are needed. And because the system is built on a modular basis, new workstations and connections can be added without modifying the existing infrastructure. The system has been fire-resistance tested in accordance with EN13501-1 and EN13501-2, class Afl-s1, providing the required safety and reliability even in critical environments.
Technical specifications
Intercell meets the most stringent standards for load capacity, fire safety, and electromagnetic compatibility. Below are the key technical specifications for use in control rooms and dispatch centres.
Class EN12825
Max. load > 9 kN, deflection < 2.5mm.
EMC attenuation
Between 3 and 30 MHz. Essential in environments with a high density of electronic equipment.
Fire classification
Tested in accordance with EN13501-1 and EN13501-2.
Frequently Asked Questions
Is Intercell suitable for use in a control room or dispatch centre?
Yes, Intercell is ideally suited for control rooms and dispatch centres. The system neatly conceals all cables, power connections, and data connections beneath the floor while providing quick access at all times for modifications or repairs.
Can I access cables and connections without demolition work?
Yes, the floor panels can be removed easily without tools. Cables and connections are always quickly accessible for inspection, maintenance, or expansion — without any demolition work or disruption.
Is Intercell suitable for 24/7 environments?
Yes, Intercell is designed for continuous use. Infrastructure modifications can be carried out at a convenient time, including outside office hours, without disrupting ongoing operations.
Does Intercell hold an EMC certification?
Yes, Intercell has been tested for electromagnetic compatibility (EMC), achieving a reduction of 25 dB between 3 and 30 MHz and 20 dB between 30 and 1000 MHz. This is essential in environments with a high density of electronic communication and control systems.
Can I expand Intercell as the control room grows?
Yes, Intercell is modular and straightforward to expand. New workstations, additional screens, and extra equipment can be added without major renovation work. Cables are rerouted and new connections are added while the floor remains in place.
Is Intercell sufficiently fire-safe for use in a critical environment?
Yes, Intercell has been fire-resistance tested in accordance with EN13501-1 and EN13501-2, class Afl-s1. The system meets the most stringent fire safety standards, ensuring the required level of safety even in critical environments.
Which connections are available through the floor boxes?
Intercell offers a range of floor boxes for power and RJ45 connections. Each workstation can be equipped with the connections required, precisely where needed. A variety of insert frames is also available for specific connection requirements.